Inspection Standards & Storage

1. The product can be stored at 25℃ room temperature and 50% relative humidity (RH) for 1 year or longer from the date of production if it is sealed with two-layer packing and placed in a box. The initial moisture content produced during the production process is between 0.2 and 0.5%. (The domestic industrial standard is less than 4%.)

2. Moreover, when DESIPACK STYLE NO. MS26507-1 is delivered, its humidity measurement card must be attached to it. The card’s colors (blue and pink) stand for “good” and “bad,” respectively, allowing the user to check the card replacement time.

3. The input time depends on the production flow, and the remaining product must be sealed if not in use. For long-term storage, the product must be sealed in a two-layer vinyl bag and stored in a dry place. The product should be used up within 6 months after it is opened.

DESIPAK’s Absorption Test by Time (Moving state at 40-95% humidity)

After
1 hour
After
2 hour
After
3 hour
After
4 hour
After
5 hour
After
6 hour
After
10 hour
After
24 hour
humidity
40%
humidity
35%
humidity
30%
humidity
29%
humidity
28%
humidity
25%
humidity
15%~20%
humidity
10%~20%

※ The humidity after X hour is the elapsed humidity in a sealed state.